Este sitio Web utiliza cookies propias y de terceros con objeto de mejorar la experiencia de navegación. Si continúa navegando estará aceptando de forma expresa el uso de estas cookies. Puede obtener más información en nuestra página Uso de Cookies

Accept Reject

Home   >  References

DESIGN, GEOMETRIC ANALYSIS AND CFD STUDY OF THE SEAWATER PUMP HOUSE FOR THE SOUTHERN LIMA DESALINATION PLANT

Submarine Pipes

  • Start Date / End Date: 2015
  • Place: Lima (Peru)
  • Scope: Hydraulic design and CFD Analysis
  • Description:

    The job defines the geometric configuration of the Southern Lima Desalination Plant pump house as part of the project entitled "Provision of Sanitation Services for the Southern Districts of Lima". A CFD study is also done with different alternatives. The main characteristics of the chamber are:
               • 5 intake channels (two reserve ones)
               • Three pumps working simultaneously
               • Channel width: 1.5 m
               • House clearance: 10.35 m (-4.6 to +5.75)
               • Maximum flow rate: 1m3/s
               • Diameter of the inlet pipe 1 m


 IMAGES OF THE PROJECT

 

 RELATED PROJECTS

See more projects
MARINE CLIMATE AND RECIRCULATION STUDY USING A DIGITAL MODEL TO ADAPT ...
CONSTRUCTION PROJECT FOR THE UNDERWATER PIPES AT THE SPENCE GROWTH DES...
WAVE STUDY AND RECIRCULATION STUDY FOR DIFFERENT DESALINATION PLANTS I...